Flexible Configurations
Choose from PM2.5, CO2, TVOC, temperature and humidity sensing combinations to match different HVAC control strategies.
The A54 Series is a compact air quality sensing platform designed for HVAC equipment integration. Select the right combination of PM2.5, CO2, TVOC, temperature and humidity sensing for fresh-air units, AHU systems and smart ventilation control.
From dedicated PM2.5 and CO2 sensing to a complete 5-in-1 IAQ configuration, the A54 Series helps HVAC equipment manufacturers select the right sensing combination without changing the overall integration approach.
Choose from PM2.5, CO2, TVOC, temperature and humidity sensing combinations to match different HVAC control strategies.
A unified enclosure concept simplifies mechanical integration across different HVAC equipment models.
Stable RS485 data output supports connection with fresh-air units, AHU controllers and distributed HVAC control systems.
Suitable for indoor air quality monitoring, ventilation management, filtration monitoring and comfort-condition sensing.
Modern ventilation systems need more than basic temperature sensing. By monitoring particulate matter, carbon dioxide, volatile organic compounds and comfort conditions, HVAC equipment can respond more intelligently to indoor air quality changes and support more effective ventilation management.
Monitor airborne particles to support filtration-performance evaluation and indoor particle control.
Use CO2 concentration as an input for ventilation adjustment and occupancy-related fresh-air control.
Detect changes in indoor volatile organic compounds and support responsive ventilation strategies.
Track indoor environmental conditions to support HVAC regulation and climate management.
The A54 Series continuously measures indoor air quality parameters and transmits sensor data through an RS485 interface. HVAC controllers can use the data to support ventilation adjustment, filtration monitoring and indoor air quality management strategies.
Indoor air passes through rooms, ducts or HVAC airflow paths.
A54 identifies PM2.5, CO2, TVOC, temperature and humidity data.
Sensor data is sent through RS485 to the HVAC control system.
HVAC equipment updates ventilation, filtration and IAQ logic.
A54 sensors provide measurement data inputs. Control actions are executed by the HVAC control system according to the configured strategy.
From basic environmental monitoring to complete indoor air quality sensing, the A54 Series offers multiple configurations for different HVAC product requirements.

Complete IAQ sensing platform for fresh-air units, AHU systems and smart ventilation control.

Balanced sensing configuration for particle monitoring, CO2-based ventilation and comfort-condition management.

Efficient environmental sensing for particulate monitoring and indoor comfort-condition management.

Dedicated particulate sensing node for ventilation cleanliness and indoor air quality monitoring.

Dedicated NDIR CO2 sensing solution for demand-controlled ventilation and HVAC air quality management.

Compact comfort-condition sensor for HVAC environmental monitoring applications.
Compare sensing parameters and application positioning to select the most suitable A54 configuration for your HVAC equipment.
| Model | PM2.5 | CO2 | TVOC | Temperature | Humidity | RS485 | Recommended Use |
|---|---|---|---|---|---|---|---|
| A54-20 | Yes | Yes | Yes | Yes | Yes | Yes | Complete HVAC IAQ monitoring |
| A54-23 | Yes | Yes | - | Yes | Yes | Yes | Fresh-air and AHU control |
| A54-22 | Yes | - | - | Yes | Yes | Yes | Particle and comfort monitoring |
| A54-21 | Yes | - | - | - | - | Yes | Dedicated PM2.5 monitoring |
| A54-24 | - | Yes | - | - | - | Yes | CO2-based ventilation control |
| A54-25 | - | - | - | Yes | Yes | Yes | Basic environmental sensing |
Select a sensing configuration based on the type of HVAC equipment and the required indoor air quality strategy.

Monitor indoor particle concentration, CO2 levels and comfort conditions to support intelligent fresh-air management.
Recommended: A54-20 · A54-23 · A54-24

Provide air quality data inputs for AHU controllers and building ventilation strategies.
Recommended: A54-20 · A54-23 · A54-22

Integrate compact sensing nodes into ventilation equipment for continuous environmental monitoring.
Recommended: A54-20 · A54-22 · A54-25

Monitor airborne particles and environmental conditions to support filtration-performance evaluation and indoor air quality management.
Recommended: A54-21 · A54-22 · A54-20
For HVAC systems that require a more complete indoor air quality picture, the A54-20 integrates PM2.5, CO2, TVOC, temperature and humidity sensing in one compact enclosure. It is suitable for fresh-air units, AHU systems and smart ventilation equipment that need multiple environmental data inputs from a single sensor node.
The A54 Series is designed to help HVAC equipment manufacturers build scalable sensing solutions across different product tiers and application requirements.
Multiple sensing configurations share a consistent enclosure concept, simplifying integration across different HVAC equipment models.
Start with a dedicated PM2.5 or CO2 sensor, or select a multi-in-one IAQ node for more advanced HVAC systems.
RS485 output supports stable data transmission and straightforward connection to HVAC control architectures.
A compact sensing platform helps equipment manufacturers streamline product planning and reduce repeated integration work.
An HVAC indoor air quality sensor can measure one or more environmental parameters, such as PM2.5, CO2, TVOC, temperature and humidity. The required configuration depends on the ventilation strategy and the type of HVAC equipment.
The A54-20 is the most complete model in the A54 Series. It combines PM2.5, CO2, TVOC, temperature and humidity sensing in one compact module.
For CO2-based ventilation strategies, the A54-24 provides dedicated CO2 sensing. For systems that also require PM2.5 and comfort-condition monitoring, the A54-23 or A54-20 may be more suitable.
Yes. The A54 Series is designed for HVAC equipment integration, including fresh-air units, air-handling units and smart ventilation systems.
The A54 Series supports RS485 communication for integration with HVAC controllers and equipment control systems.
The A54-21 is a dedicated PM2.5 sensor. For applications that also require temperature and humidity monitoring, the A54-22 is a suitable option.
A multi-in-one sensor combines several environmental parameters in a compact enclosure. This can simplify equipment integration and provide HVAC controllers with a broader set of indoor air quality data.
Start by identifying the required sensing parameters and the HVAC control strategy. For basic particle monitoring, select A54-21. For CO2-based ventilation, select A54-24. For a complete IAQ solution, select A54-20.
Explore practical resources for selecting air quality sensors and designing HVAC indoor air quality monitoring strategies.
Explore how air sensors integrated into 86 controllers enable room-level air quality monitoring, HVAC linkage, fresh-air coordination and closed-loop control.
Read Article
Learn how multi-in-one air quality modules handle integration, selection, system connection and calibration for HVAC and commercial air monitoring.
Read Article
Compare NDIR and MOS sensors across sensing principles, selectivity, stability, CO2 measurement, VOC interpretation and air quality applications.
Read Article
Understand how CO2 sensors use NDIR infrared absorption to measure concentration and support HVAC, fresh-air and environmental monitoring.
Read ArticleShare your sensing parameters, HVAC control strategy, installation position and communication requirements. Our engineering team will recommend a suitable A54 sensor configuration for your HVAC equipment platform.